PCB Trace Width Calculator
= 35.0 µm
°C
°C
Trace Width
11.83 mils
300.4 µm
Area
16.30 mil²
0.010514 mm²
Resistance
43.29 mΩ/in
1.704 mΩ/mm
Voltage Drop
43.29 mV/in
1.704 mV/mm
Power Loss
43.29 mW/in
1.704 mW/mm
Note: Actual current capacity depends on PCB layout, nearby copper (heatsinking), thermal conductivity of substrate/solder mask, and airflow. Use these values as a starting point and verify with thermal analysis.
Reverse: Current Capacity
Width:mils(254.0 µm)
→0.89 Amax current
Show formulas
First, calculate the Area:
Then, calculate the Width:
IPC-2221 external layers:
k = 0.048, b = 0.44, c = 0.725
Variables:
I = Current (A), TRise = Temp rise (°C)
A = Area (mil²), t = Thickness (oz), W = Width (mils)
Reference:
1 oz copper ≈ 1.378 mils ≈ 35 µm
Want to learn more?
EE Tools is not affiliated with these websites. Just sharing helpful resources.